This paper suggested the electric potential method with a bridge circuit concept for the detection of the location and crack growth of carbon fiber reinforced composites to reduce the measurement numbers. 2 pairs of electrodes were fabricated on the center cracked thin composite plates, and potential changes at one pair of adjacent electrodes were observed while external voltage input was applied to the other pair of adjacent electrodes. The effects of the size and interval of electrodes, location and propagating direction of center cracks were investigated by experiments and finite element analyses. Detectable crack size was influenced by the electrode interval rather than the electrode size, and crack detection was enhanced as the size and interval of electrodes were smaller. Besides, output potential changes were larger as the crack grew and was nearer the voltage input electrodes.
본 논문에서는 탄소섬유 복합재료의 균열의 위치 및 성장을 감지하기 위하여 브리지 회로 개념이 적용된 전기 전위법을 제안하였다. 중앙 관통 균열을 가진 복합재료 박판 시험편에 두 쌍의 전극을 생성하였으며, 브리지 회로 개념을 적용하여 한쌍의 전극에 외부 전압을 인가하고 다른 한 쌍의 전극으로부터 출력 전압 변화를 관찰하였다. 실험과 유한요소해석을 통하여 전극의 크기와 간격, 균열의 위치와 크기 및 성장 방향의 영향을 고찰하였다. 검출 가능한 균열의 크기는 전극의 크기 보다는 전극의 간격에 의한 영향이 더 컸으며, 전극의 크기와 간격이 작을수록 균열의 검출 능력이 우수하였다. 또한, 균열 크기가 증가할 수록, 입력 전극과 가까울수록 출력 전압의 변화가 큼을 관찰할 수 있었다.
Keywords: electric potential method, bridge circuit, carbon fiber reinforced
Keywords: 전기 전위법, 브리지 회로 , 탄소섬유 복합재료