Original Article
  • Impact Damage Detection in a Composite Stiffened Panel Using Built-in Piezoelectric Active Sensor Arrays
  • Chan Yik Park*+, Changmin Cho*
  • 배열 압전 능동 센서를 이용한 복합재 보강판의 충격 손상 탐지
  • 박찬익(국방과학연구소), 조창민(국방과학연구소)
Abstract
Low-velocity impact damage in a composite stiffened panel was detected using built-in piezoelectric active sensor arrays. Using these piezoelectric active sensors, various diagnostic signals were generated to propagate Lamb waves through the structure and the responses were picked up to detect changes in the structure's vibration signature due to the damage. Three algorithms – ADI(Active Damage Interrogation), TD RMS (Time Domain Root Mean Square) and STFT (Short Time Fourier Transform) – were examined to express the features of the signal changes as one damage index. From damage detecting tests, two impact induced delaminations were detected and the location was estimated with the algorithms and diagnostic signals.

복합재 보강판에 영구히 부착된 배열 압전 능동 센서를 사용하여 저속 충격 손상을 탐지하였다. 압전 능동센서를 사용하여 구조에 램파를 전파시키기 위한 다양한 진단신호를 생성하였으며, 손상으로 인한 구조 진동의 특성 변화를 탐지하기 위하여 그 응답을 측정하였다. 이 신호 변화 특징을 한 개의 손상 지수로 표현하기 위하여 3가지 알고리즘–ADI(Active Damage Interrogation), TD RMS (Time Domain Root Mean Square), STFT(Short Time Fourier Transform) –이 검토되었다. 손상 탐지 시험을 수행하여, 사용한 기법과 진단신호로 저속 충격으로 인한 두 개의 층간분리를 탐지하였으며, 그 위치를 추정하였다.

Keywords: Structural health monitoring, Composite materials, Active sensors

Keywords: 구조건전성모니터링, 복합재료, 능동센서

This Article

  • 2007; 20(6): 21-27

    Published on Dec 31, 2007

Correspondence to

  • E-mail: